EJOT VSD-8U V
Renovation of two-shell masonry
When renovating old building structures and before installing ETIC systems legislation demands an inspection of the structural safety of the wall. The structural safety has to be restored where necessary. Double-leaf walls
with outer leafs, where the connection of the two leafs is often compromised due to corrosion of the cavity wall ties, can be restored to structural safety with the EJOT VSD-8U V.The zinc-plated steel screw of the EJOT VSD-8U V
with building authorities approval, enables a renovation of the outer leaf of outdoor buildings, in an industrial atmosphere and close to the coast. After renovation of the outer leaf, an additional facade system with thermal insulation (e.g. ETICS) with a thickness of at least 60 mm has to be applied. Ventilation behind the outer leaf has to be prevented also. Our special service for you:For safety reasons, rebuilding the stability of a weather shell or a facing shell should be calculated by an engineer. Our technical service is happy to help you choose the right renovation solution and delivers all details necessary.
Renovation anchor for prewall shells
|
|
Technical data
| drill hole depth h1 ≥ | ld + 10 mm |
| anchorage depth hef ≥ | 70 mm |
| drill nominal diameter | 8 mm |
| Approval code | Z-21.2-1562 |
Approved substrates
| concrete C 12/15 acc. to EN 206-1 |
| concrete C 16/20 - C 50/60 acc. to EN 206-1 |
| clay brick (Mz) acc. to DIN 105 |
| solid lime sandstone (KS) acc. to DIN EN 106 |
| solid brick of lightweight concrete (V) acc. to DIN 18152 |
| vertical coring brick (Hlz) acc. to DIN 105 |
| perforated lime sandstone (KSL) acc. to DIN EN 106 |
| hollow block of lightweight concrete (HbL) acc. to DIN 18151 |
Product range
| distance between interior and exterior shell (mm) | nominal length (mm) | product name |
| 20 | 205 | EJOT VSD 8 x 205 |
| 40 | 225 | EJOT VSD 8 x 225 |
| 60 | 245 | EJOT VSD 8 x 245 |
| 80 | 265 | EJOT VSD 8 x 265 |
| 100 | 285 | EJOT VSD 8 x 285 |
| 120 | 305 | EJOT VSD 8 x 305 |
Use of steel screws possible if a thermal insulation (ETICS, rear ventilated facades) is installed
afterwards (please check the approval for details).
Installation
Note: The EJOT VSD is installed in the centre of the stone.
Minimum thickness of the facing shell: 115 mm.