Renovation of two-shell masonry

When renovating old building structures and before installing ETIC systems legislation demands an inspection of the structural safety of the wall. The structural safety has to be restored where necessary. Double-leaf walls

with outer leafs, where the connection of the two leafs is often compromised due to corrosion of the cavity wall ties, can be restored to structural safety with the EJOT VSD-8U V.

The zinc-plated steel screw of the EJOT VSD-8U V

with building authorities approval, enables a renovation of the outer leaf of outdoor buildings, in an industrial atmosphere and close to the coast. After renovation of the outer leaf, an additional facade system with thermal insulation (e.g. ETICS) with a thickness of at least 60 mm has to be applied. Ventilation behind the outer leaf has to be prevented also.

Our special service for you:

For safety reasons, rebuilding the stability of a weather shell or a facing shell should be calculated by an engineer. Our technical service is happy to help you choose the right renovation solution and delivers all details necessary.


Renovation anchor for prewall shells

  • building authorities approved anchor for renovating

    double-leaf masonry

  • double expansion wall anchor: simultaneous fastening in load-bearing wall and outer leaf

  • clean and fast installation (no mortar required)

  • universal expansion zone: secure installation into

    concrete load-bearing shells, solid and perforated brick

    masonry

  • also applicable with low outside temperatures

 
 

Technical data

drill hole depth h1        ld + 10 mm
anchorage depth hef 70 mm
drill nominal diameter 8 mm
Approval code Z-21.2-1562

 

Approved substrates

concrete C 12/15 acc. to EN 206-1
concrete C 16/20 - C 50/60 acc. to EN 206-1
clay brick (Mz) acc. to DIN 105
solid lime sandstone (KS) acc. to DIN EN 106
solid brick of lightweight concrete (V) acc. to DIN 18152
vertical coring brick (Hlz) acc. to DIN 105
perforated lime sandstone (KSL) acc. to DIN EN 106
hollow block of lightweight concrete (HbL) acc. to DIN 18151

 

Product range

distance between
interior and exterior shell (mm)
nominal length (mm) product name
20 205 EJOT VSD 8 x 205
40 225 EJOT VSD 8 x 225
60 245 EJOT VSD 8 x 245
80 265 EJOT VSD 8 x 265
100 285 EJOT VSD 8 x 285
120 305 EJOT VSD 8 x 305

Use of steel screws possible if a thermal insulation (ETICS, rear ventilated facades) is installed
afterwards (please check the approval for details).

 

Installation

Note: The EJOT VSD is installed in the centre of the stone.
Minimum thickness of the facing shell: 115 mm.